Fluid Fill Angle 0° 50° 0° Recommended Fluids ➀ ISO Viscosity Grade, Petroleum Oils (R & O) ................................................................. 46 ISO Viscosity Grade, Synthetic Oils ............................................................................... 32 Viscosity at 104°F(40°C) — 46 cSt (215 SSU) Viscosity Index — Equal to or greater than 95. HIGH LEVEL OF FILL Pour Point — Must be 5°F (3°C) lower than minimum starting temperature. 100° LOW LEVEL OF FILL Fluid couplings are shipped without fluid. Fluid is added during installation. The installer adds fluid, obtained locally, and that meets “Recommended Fluids” specifications listed on this page. When application data (horsepower, rpm, start factor) is provided, the fluid coupling will include an orange sticker with fill angle (degrees), and approximate fill quantity (fluid ounces). If no orange sticker is present, a fill angle may be obtained from the Quick Selection tables in this catalog (pages 14-19). Using fill angle as a starting point, approximate fill quantity (fluid ounces) may be obtained from the table below. Fluid couplings include an angle finder (P/N 1224653) and installation instructions. Remove the fill plug, place the angle finder on the flat boss at the fill plug location, and rotate the coupling to the specified fill angle (degrees from vertical). With the coupling in this position, add fluid until it reaches the lip of the fill hole. As shown above, a low fill angle (example is 50°) corresponds to a high level of fill. A high fill angle (example is 100°) corresponds to a low level of fill. The level of fill in the coupling determines the start factor, percent slip, starting torque, stall torque, ... essentially all performance characteristics of the coupling. After installation and operation, fine-tuning of the fill level may be necessary, based on load readings or other site variables. In general, increasing the fill level (decreasing the fill angle) increases start factor/start torque/stall torque, shortens time required to accelerate the load to operating speed, and reduces percent slip. Reducing the fill level (increasing the fill angle) decreases start factor/start torque/stall torque, increases time required to accelerate the load to operating speed, and increases percent slip. Convert Fluid Ounces to Weight (lb) There are 128 Fluid Ounces per Gallon Weight (lb) = Fluid oz x 0.0648 x specific gravity of the fluid Example: Size 1480HFN @ 70 degree fill angle (See table below) Weight = 413 fluid oz x 0.0648 x 0.87 = 23.3 lb of fluid Flash Point — 400°F (204°C) when using 140°C and/or 180°C fusible plugs. Flash Point — 425°F (218°C) when using 200°C fusible plugs at both fill and drain holes. Specific Gravity — 0.87 Antioxidant and Anti-foaming Additives Petroleum Oils (R & O) Amoco Oil Company BP Oil Company For Ambient Temperatures 20°F to 125°F (-6°C to 52°C) Manufacturer Fluid Chevron Products Company Exxon Company, USA Mobil Oil Corporation Petro-Canada Products Shell Oil Company Texaco Lubricants Company 76 Lubricants Company Amoco Oil Company Mobil Oil Corporation Conoco Incorporated Exxon Company, USA Mobil Oil Corporation Texaco Lubricants Company Mobil Oil Corporation Chevron Citgo American Industrial Oil 46 HL-C46 Hydraulic Oil AW 46 Teresstic 46 Mobil Fluid 424 Harmony 46 Turbo T 46 Rando Oil HD 46 76 Unax AW 46 For Ambient Temperatures -20°F to 125°F (-28°C to 52°C) Manufacturer Fluid American Industrial Oil 46 Mobilfluid 424 For Ambient Temperatures -40°F to 125°F (-40°C to 52°C) Manufacturer Synthetic Oils and Synthetic Transmission Fluids Fluid Syncon R&O 32 Teresstic SHP 32 SHC 624 Pinnacle 32 Synthetic ATF Synthetic All Weather THF Transgard Fluid 250 Automatic Transmission Fluids (Dexron or Mercon Oils, etc.) For Ambient Temperatures -40°F to 125°F (-40°C to 52°C) NOTICE: Automatic Transmission Fluids below can only be used with two 140°C fusible plugs Mobil Texaco (Havoline) Citgo Multi-purpose ATF Mercon/Dexron-III or ATF Transgard ATF, Type F ATF Type A and Type Dexron II, llD, llE, lll, Mercon M-891205 and M-921253 ➀ Refer to the Factory for use of fire resistant fluids. Recommended fluids are typical products only, and should not be construed as exclusive recommendations. Approximate Fill Quantity (Fluid Ounces) Fill Angle (Degrees) from Vertical 50 55 60 65 70 75 80 85 90 95 100 105 Types HFN & HFR 185 34 33 31 30 28 26 24 22 20 18 16 – 30 (521-110) 235 65 63 60 57 53 50 47 43 39 34 30 – 270 88 83 78 73 69 65 61 57 52 47 44 – 320 142 136 128 120 113 105 98 90 82 75 72 – 370 239 233 221 207 192 177 162 149 136 124 115 – 1420 1480 1584 1660 2760 352 331 311 291 271 247 230 216 196 172 156 – 524 497 473 443 413 385 348 321 294 267 247 – – Coupling Size 370 862 1555 2147 303 835 1481 2012 292 801 1413 1894 276 754 1319 1792 257 700 1234 1640 237 649 1150 1539 218 592 1065 1420 200 544 504 456 423 – 984 1336 185 910 1217 172 825 1099 159 754 1015 142 – 125 Type HFD 710 1136 1833 2645 N/A 663 1096 1762 2492 N/A 629 1055 1684 2360 524 578 531 497 460 419 379 335 291 245 977 1569 2164 484 910 1461 1985 443 832 1359 1846 406 751 1248 1701 369 693 1150 1600 342 639 1048 1454 315 585 528 485 893 1322 294 876 1177 271 783 1015 247 N/A N/A Type HFDD 1420 1480 1584 1660 2760 1420 1480 1584 1660 2760 440 426 399 382 348 328 298 281 252 227 203 179 N/A N/A N/A N/A N/A N/A 795 1322 1924 2705 727 1224 1789 2503 663 1130 1650 2300 605 1045 1529 2131 561 521 480 443 402 365 964 1403 1961 896 1295 1809 822 1184 1657 754 1048 1505 687 622 947 1353 859 1228 NOTE: Dimensions subject to change. Certified dimensions of ordered material furnished on request. Petroleum Oils (R & O)